High voltage cable
High voltage cables produced by SiTong CableCABLE can be used for more than 30 years. It is used for efficient transportation of high voltage transmission electricity.
Certification Standards
Implementation Standards
- IEC 60840
- IEC 60287
- IEC 62067
- ICEA S-108-720
- AEIC CS9
- IEC 60228
- HRN HD 632
Product Introduction
High Voltage Cable Overview
High-voltage cable is a kind of power cable, mostly used for power transmission and distribution, with a voltage level of 35kv-220kv cable. Such as high-voltage overhead power lines and underground power cables.
Construction Details
A typical high-voltage cable construction consists of:
- Core
- Inner insulation layer
- Semiconductor layer
- Steel armor
- Filler material
- Outer insulation layer
Materials used in the cables vary by purpose, but cores are typically copper or aluminum (aluminum being more common due to cost).
Product Features
- Long service life (30+ years)
- Suitable for various installations (outdoors, underground, in water, power stations, wind farms, industrial, submarine transmission)
- Used in electrostatic painting, electrostatic beneficiation, static flocking, and other weak current high voltage DC devices
Types Available
- British Standard
- American Standard
- European Standard
- Custom types available
Standards Compliance
- IEC 60840
- IEC 60287
- IEC 62067
- ICEA S-108-720
- AEIC CS9
Technical Specifications
35kv-220kv Underground XLPE Insulated Power Cable
- Voltage: 35kv-220kv
- Conductor: Class 2 copper or aluminum conductor
- Conductor Screen: Extruded semi-conductive XLPE
- Cross-Section: 150-800mm2
- Insulation: XLPE
- Insulation Screen: Semi-conductive XLPE
- Separator: Water swellable semi-conductive tape
- Screen: Copper wire screen with counter helix of copper tape
- Sheath: HDPE (High-Density Polyethylene)
Temperature Ratings
- Maximum Conductor Temperature In Service: +90°C
- Short Circuit Temperature: +250°C
- Operating Temperature: -30°C to 90°C
Testing Parameters
- Partial Discharge Test: ≤5 pC at 1.5 U0
- Power Frequency Voltage Test: 2.5U0 for 30 min
- Non-metal Sheath DC Voltage Test: 25kV for 1 min
Customization Options
SiTong Cable Cable can customize cable products to meet specific requirements including:
- Cable voltage
- Conductor material
- Insulation and sheath material
- Shielding type
- Armor type
- Installation environment
- Application requirements
Technical Specifications
35kv-220kv Underground XLPE Insulated Power Cable
Parameter | Value |
---|---|
Voltage | 35kv-220kv |
Conductor | Class 2 copper or aluminum |
Conductor Screen | Extruded semi-conductive XLPE |
Cross-Section | 150-800mm2 |
Insulation | XLPE |
Insulation Screen | Semi-conductive XLPE |
Separator | Water swellable semi-conductive tape |
Screen | Copper wire screen with counter helix of copper tape |
Sheath | HDPE |
Temperature Ratings
Parameter | Value |
---|---|
Maximum Conductor Temperature | +90°C |
Short Circuit Temperature | +250°C |
Operating Temperature | -30°C to +90°C |
Testing Parameters
Test | Requirement |
---|---|
Partial Discharge Test | ≤5 pC at 1.5 U0 |
Power Frequency Voltage Test | 2.5U0 for 30 min |
Non-metal Sheath DC Voltage Test | 25kV for 1 min |
Application Fields
High voltage power transmission
Power distribution networks
Industrial power supply
Wind farm connections
Submarine power transmission
Electrostatic applications
Power stations
Packaging & Shipping
All cables will be packaged in different materials based on their outer diameter and net weight, and can be customized according to requirements