Armored Instrument Cable
Paired or Triplex Instrument Cable, Screening Control Cable, XLPE Insulation, Armored Control Cable, Instrument Cable
Certification Standards
Implementation Standards
- BS / PAS 5308
- BS EN 60228
- BS 6234
- BS EN 50363
- BS EN / IEC 60332-1
- BS EN / IEC 60332-3-24
Product Introduction
Armoured Instrumentation Cable
Armoured Instrumentation Cable is applicable to control cable products for instrumentation with AC-rated voltage 450/750V and below. The shielded cable for the roving detection device adopts a twisted aluminum-plastic composite film shield and copper wire braid shield with superior anti-interference performance, which is widely used in computer measurement and control devices. And armored instrumentation cables are also widely used between inverter power supplies and inverter motors.
The armored LSZH version is generally used when there is an increased risk of mechanical damage, and the galvanized steel wire armor provides excellent protection.
Application
This kind of Armoured Instrument Cable is suitable for instruments and other electrical equipment in the signal transmission and control circuit. The armored Instrument cables are generally used for outdoor installation and are suitable for wet and damp areas.
Standard
- BS / PAS 5308
- BS EN 60228
- BS 6234
- BS EN 50363
- BS EN / IEC 60332-1
- BS EN / IEC 60332-3-24
Construction
- Conductor: Annealed or tinned copper
- Insulation: XLPE (cross-linked polyethylene) or PE
- Pairing: Two insulated wires are twisted together uniformly, and the laying distance does not exceed 100 mm
- Binding Tape: PETP transparent tape
- Collective Shielding: paste aluminum/polyester tape on paired metal pairs and make contact with tinned copper drain wire, thickness 0.5 mm²
- Inner Sheath: LSZH (Low Smoke Zero Halogen) Sheath
- Amour: Galvanized steel armor
- Cable Outer Sheath: LSZH (Low Smoke Zero Halogen) Sheath is flame retardant, conforms to IEC60332-3-22, halogen-free, conforms to IEC60754-1, low smoke emissions, conforms to IEC61034-1-2
- Sheath Color: black or blue
- AC Rated Voltage: Uo/U 450/750V
- Maximum Working temperature: not more than 70℃
- Laying Temperature: not less than 0℃
- Allowable Bending Radius: 10 times the outer diameter of the cable for non-armored cable at least; copper tape shield or steel tape armored cable is at least 12 times the outer diameter of the cable.
Instrument Cable Types
- KJYVP polyethylene insulated PVC sheathed braided shielded instrumentation control cable
- KJYVPR polyethylene insulated PVC sheathed braided shielded instrumentation control flexible cable
- KJYVP2 polyethylene insulated PVC sheathed copper tape shielded instrumentation control cable
- KJYVP2R polyethylene insulated PVC sheathed copper tape shielded instrumentation flexible cable
- KJYVP3 polyethylene insulated PVC sheathed aluminum-plastic composite film shielded instrumentation control cable
- KJYVPR Polyethylene-insulated PVC sheathed aluminum-plastic composite film shielded instrumentation flexible cable
- KJYVP polyvinyl chloride insulated PVC sheathed braided shielded instrumentation control cable
- KJYVPR polyvinyl chloride insulated PVC sheathed braided shielded control flexible cable for instrumentation
- KJYVP2 polyvinyl chloride insulated polyvinyl chloride sheathed copper tape shielded instrumentation control cable
- KJYVP2R polyvinyl chloride insulated polyvinyl chloride sheathed copper tape shielded instrumentation flexible cable
- KJYVP3 polyvinyl chloride insulated polyvinyl chloride sheathed aluminum-plastic composite film shielded instrumentation control cable
- KJYVPR polyvinyl chloride insulation PVC sheathing aluminum-plastic composite film shielding instrumentation control cable
Technical Specifications
Construction Details
Conductor | Annealed or tinned copper, sizes: 0.5mm² and 0.75mm² mulitistranded(Class 5), |
0.5 mm², 1.0 mm² solid(Class 1), 1.5mm² or 2.5mm², multistranded(Class 2) to BS6360 | |
Insulation | PE (Polyethylene) type 03 to BS6234 |
Pairing | Two or three insulated conductors uniformly twisted together with a lay not exceeding 100mm |
Colour code | See technical information |
Binder tape | PETP transparent tape |
Collective screen | Aluminium/polyester tape is applied over the laid up pairs metallic side down in contact with tinned copper drain wire, 0.5mm² |
Outer sheath | PVC Sheath, type TM 1 or type 6 to BS 6746 |
Sheath colour | Black or blue |
Application Fields
Signal transmission and control circuits for instruments and other electrical equipment
Outdoor installation in wet and damp areas
Computer measurement and control devices
Connection between inverter power supplies and inverter motors
Packaging & Shipping
All cables will be packaged in different materials based on their outer diameter and net weight, and can be customized according to requirements