LV ABC Cable
To be used at voltages of 600 volts or less phase to phase and at conductor temperatures not to exceed 75°C for PE insulated Conductors or 90°C for crosslinked polyethylene (XLPE) insulated conductors.
Certification Standards
Implementation Standards
- IEC 61089
- BS 7870
- DIN 48201
- ASTM B399
- BS EN50183
- NFC33-209
Product Introduction
Low-voltage LV ABC cable, designed for overhead power lines and room entrance wires with a rated AC pressure of 1kV and below. It has less installation, maintenance, and operating costs, which can achieve greater economic loss and provide higher security and reliability.
Application:
This is a kind of climate-bearable PVC, HDPE, and XLPE insulated aerial cables of copper core, aluminum core, or aluminum alloy core, suitable for overhead power lines of AC rated voltage Uo/U 0.6/1KV and below. It is widely used in power transmission lines and electricity distribution lines with various voltage levels because they have such good characteristics as simple structure, convenient installation and maintenance, and low-cost large transmission capacity. And they are also suitable for laying across rivers valleys and places where special geographical features exist.
Construction:
- Conductor: copper, aluminum, aluminum alloy
- Insulation: PVC, HDPE, XLPE
Standards:
- IEC 61089
- BS 7870
- DIN 48201
- ASTM B399
- BS EN50183
- NFC33-209
Technical Specifications
Conductor and Insulation Specifications
| Nominal cross-section area of conductor(mm²) | Single wire Min. No of conductor | Conductor O.D.(reference value)/mm | Nominal thickness of insulation(mm) |
|---|---|---|---|
| 10 | 6 | 3.8 | 1.0 |
| 16 | 6 | 4.8 | 1.2 |
| 25 | 6 | 6.0 | 1.2 |
| 35 | 6 | 7.0 | 1.4 |
| 50 | 6 | 8.4 | 1.4 |
| 70 | 12 | 10.0 | 1.4 |
| 95 | 15 | 11.6 | 1.6 |
| 120 | 18 | 13.0 | 1.6 |
| 150 | 18 | 14.6 | 1.8 |
| 185 | 30 | 16.2 | 2.0 |
| 240 | 34 | 18.4 | 2.2 |
Resistance and Breaking Load (Copper)
| The Max. Resistance of conductor at 20°C(Ω/km) | The Min, resistance of insulation at rated temperature | Breaking load of single core | ||
|---|---|---|---|---|
| Hard copper | Soft copper | 70°C | 90°C | Hard copper |
| 1.906 | 1.83 | 0.0067 | 0.67 | 3471 |
| 1.198 | 1.15 | 0.0065 | 0.65 | 5486 |
| 0.749 | 0.727 | 0.0054 | 0.54 | 8465 |
| 0.540 | 0.524 | 0.0054 | 0.54 | 11731 |
| 0.399 | 0.387 | 0.0046 | 0.46 | 16502 |
| 0.276 | 0.268 | 0.0040 | 0.40 | 23461 |
| 0.199 | 0.193 | 0.0039 | 0.39 | 31759 |
| 0.158 | 0.153 | 0.0035 | 0.35 | 39911 |
| 0.128 | 0.124 | 0.0035 | 0.35 | 49505 |
| 0.1021 | 0.0991 | 0.0035 | 0.35 | 61846 |
| 0.0777 | 0.0754 | 0.0034 | 0.34 | 79823 |
Cable Outer Diameter
| No.section area of conductor (mm²) | Single wire Min. No Of conductor | Conductor O.D. (reference value)/mm | Cable Max. Average outer diameter(mm) |
|---|---|---|---|
| 10 | 6 | 3.8 | 6.5 |
| 16 | 6 | 4.8 | 8.0 |
| 25 | 6 | 6.0 | 9.4 |
| 35 | 6 | 7.0 | 11.0 |
| 50 | 6 | 8.4 | 12.3 |
| 70 | 12 | 10.0 | 14.1 |
| 95 | 15 | 11.6 | 16.5 |
| 120 | 15 | 13.0 | 18.1 |
| 150 | 15 | 14.6 | 20.2 |
| 185 | 30 | 16.2 | 22.5 |
| 240 | 30 | 18.4 | 25.6 |
| 300 | 30 | 20.8 | 27.2 |
| 400 | 53 | 23.2 | 30.7 |
Resistance and Breaking Load (Aluminum)
| The Max. Resistance of conductor at 20°C (Ω/km) | The Min. resistance of insulation at rated temperature | Breaking load of single-core | |||
|---|---|---|---|---|---|
| Aluminum | Aluminum alloy | 70°C | 90°C | Aluminum | Aluminum alloy |
| 3.08 | 3.574 | 0.0067 | 0.67 | 1650 | 2514 |
| 1.91 | 2.217 | 0.0065 | 0.65 | 2517 | 4022 |
| 1.20 | 1.393 | 0.0054 | 0.54 | 3762 | 6284 |
| 0.868 | 1.007 | 0.0054 | 0.54 | 5177 | 8800 |
| 0.641 | 0.744 | 0.0046 | 0.46 | 7011 | 12569 |
| 0.443 | 0.514 | 0.0040 | 0.40 | 10354 | 17596 |
| 0.320 | 0.371 | 0.0039 | 0.39 | 13727 | 23880 |
| 0.253 | 0.294 | 0.0035 | 0.35 | 17339 | 30164 |
| 0.206 | 0.239 | 0.0035 | 0.35 | 21033 | 37706 |
| 0.164 | 0.190 | 0.0035 | 0.35 | 26732 | 46503 |
| 0.125 | 0.145 | 0.0034 | 0.34 | 34679 | 60329 |
| 0.100 | 0.116 | 0.0033 | 0.33 | 43349 | 75411 |
| 0.0778 | 0.0904 | 0.0032 | 0.32 | 55707 | 100548 |
Application Fields
Overhead power lines
Room entrance wires
Power transmission lines
Electricity distribution lines
Laying across rivers and valleys
Packaging & Shipping
All cables will be packaged in different materials based on their outer diameter and net weight, and can be customized according to requirements